Evaluation of thoracic impedance trends for implant-based remote monitoring in heart failure patients - Results from the (J-)HomeCARE-II Study

Fecha de publicación:

Autores de FIHGUV

Participantes ajenos a FIHGUV

  • Maier, Sebastian K. G.
  • Paule, Stefan
  • Jung, Werner
  • Koller, Marcus
  • Ventura, Rodolfo
  • Bordachar, Pierre
  • Garcia-Fernandez, F. Javier
  • Schumacher, Burghard
  • Lobitz, Nicole
  • Takizawa, Kaname
  • Ando, Kenji
  • Adachi, Kazumasa
  • Shoda, Morio

Unidades de Investigación

Resumen

Aims: Remote monitoring by implantable devices substantially improves management of heart failure (HF) patients by providing diagnostic day-to-day data. The use of thoracic impedance (TI) as a surrogate measure of fluid accumulation is still strongly debated. The multicenter HomeCARE-II study evaluated clinically apparent HF events in the context of remote device diagnostics, focusing on the controversial role of TI. Methods and results: We followed 497 patients (66.6 +/- 10.1 years, 77% male, QRS 139.8 +/- 36.0 ms, ejection fraction 26.8 +/- 7.0%) implanted with a CRT-D (67%) or an ICD (33%) for 21.4 +/- 8.1 months. An independent event committee confirmed 171 HF events of which 82 were used to develop a TI-based algorithm for the prediction of imminent cardiac decompensation. Highly inter-individual variations in patterns of TI trends were observed. The algorithm resulted in a sensitivity of 41.5% (50.0%) with 0.95 (1.34) false alerts per patient year, and a positive predictive value of 7.9% overall and 27.9% in the HF event group of patients. Averaged ratio statistics showed a significant pre-hospital decrease and a highly significant in-hospital increase in TI after intensified diuresis. Recurrent decompensations turned out to be preceded by a significantly stronger decrease of TI compared to first events with a higher chance for detection (63.6% sensitivity, p < 0.05). Conclusions: Overall performance in predicting imminent decompensation by monitoring TI alone is limited due to its high inter-patient variability. TI stand-alone applications should be redirected towards a target population with more advanced symptoms where post-hospital observation aimed to maintain the patient's discharge status might be the most valuable approach. (C) 2019 Elsevier Inc All rights reserved.

Datos de la publicación

ISSN/ISSNe:
0022-0736, 1532-8430

Journal of Electrocardiology  CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS

Tipo:
Article
Páginas:
100-108
PubMed:
30739055

Citas Recibidas en Web of Science: 14

Documentos

  • No hay documentos

Métricas

Filiaciones

Filiaciones no disponibles

Campos de Estudio

Compartir